<?xml version="1.0" ?>
<workspace height="100" width="100">
    <widgets expanded="False" position="left" width="1">
        <drive_explorer visible="False" selected="False" height="1"/>
    </widgets>
    <widgets expanded="True" position="right" width="582">
        <control visible="True" selected="False" height="338">
            <options display_categories="False" display_control_button="True" target_latch="True" tune_enabled="False" display_enable_homing_button="False" show_fault_reset_button="True"/>
            <registers>
                <register drive="0" subnode="1" representation="1">DRV_OP_CMD</register>
                <register drive="0" subnode="1" representation="1">DRV_STATE_CONTROL</register>
                <register drive="0" subnode="1" representation="1">CL_VEL_SET_POINT_VALUE</register>
                <register drive="0" subnode="1" representation="1">CL_VEL_PID_KP</register>
                <register drive="0" subnode="1" representation="1">CL_VEL_PID_KI</register>
                <register drive="0" subnode="1" representation="1">CL_VEL_PID_KD</register>
                <register drive="0" subnode="1" representation="1">CL_VEL_PID_KD_FILTER</register>
                <register drive="0" subnode="1" representation="1">CL_VEL_FF_KA</register>
                <register drive="0" subnode="1" representation="1">CL_VEL_PID_MAX_OUT</register>
                <register drive="0" subnode="1" representation="1">CL_VEL_PID_MIN_OUT</register>
                <register drive="0" subnode="1" representation="1">CL_VEL_REF_MAX</register>
                <register drive="0" subnode="1" representation="1">PROF_MAX_ACC</register>
                <register drive="0" subnode="1" representation="1">PROF_MAX_DEC</register>
                <register drive="0" subnode="1" representation="1">PROF_MAX_VEL</register>
            </registers>
        </control>
        <display visible="True" selected="False" height="131">
            <options refresh_time="300" display_categories="False"/>
            <registers>
                <register drive="0" subnode="1" representation="1">DRV_PROT_VBUS_VALUE</register>
                <register drive="0" subnode="1" representation="1">DRV_PROT_TEMP_VALUE</register>
                <register drive="0" subnode="1" representation="1">DRV_OP_VALUE</register>
            </registers>
        </display>
        <safety visible="True" selected="False" width="1">
            <options sto_bypass="False" safe_input_linked="False" sto_activate_sout="False"/>
        </safety>
        <signal_generator visible="False" selected="False" height="0">
            <options gen_amplitude="2" gen_offset="0" gen_disturbance_signal="CL_CUR_A_SET_POINT" gen_signal_freq="200" gen_signal_type="0"/>
        </signal_generator>
    </widgets>
    <widgets expanded="False" position="bottom" height="200">
        <errors visible="False" selected="False" width="100"/>
        <console visible="False" selected="False" width="100"/>
    </widgets>
    <main_content>
        <scope displayed="True" tab_widget="0">
            <general background_color="#000000" grid_color="#b0b0b0" grid_enabled="True" legend_enabled="True" legend_type="1" display_triggers="False" sync_x="True" layout="2"/>
            <capture_settings mode="0" refresh_time="125" sampling_time="125"/>
            <chart id="0" limit_y="False" max_y="0" min_y="0" x_log="False" y_log="False">
                <channel drive="0" color="#ff8000" subnode="1">CL_VEL_SET_POINT_VALUE</channel>
                <channel drive="0" color="#ff0000" subnode="1">CL_VEL_FBK_VALUE</channel>
                <channel drive="0" color="#00ffff" subnode="1">CL_VEL_REF_VALUE</channel>
            </chart>
            <chart id="1" limit_y="False" max_y="0" min_y="0" x_log="False" y_log="False">
                <channel drive="0" color="#80ff00" subnode="1">CL_POS_FBK_VALUE</channel>
            </chart>
        </scope>
    </main_content>
</workspace>
