Bug
-
S-curve:
-
CAP-599 A positive velocity demand appears in a negative direction movement
-
CAP-753 At the end of a movement, the velocity demand is taking the velocity set-point value
-
CAP-754 High velocity command is sent when profile is latched
-
CAP-755 Acceleration discontinuity when latching new setpoints
-
CAP-756 Overshoot occurs when latching with non-zero initial velocities
-
CAP-292 When a profile position S-curve movement ends, velocity demand is set to profiler max. velocity instead of 0 rev/s
-
-
Object dictionary:
-
CAP-721 System last error has bad data type
-
CAP-717 Some registers have incorrect names
-
CAP-705 Torque demand register is missing in CANopen
-
CAP-594 Access error, reading CANopen identification registers
-
CAP-503 Analog value is missing
-
CAP-508 Halt option code is RO and should not
-
CAP-436 CANopen register 0x1f56 has wrong value
-
CAP-408 Registers 0x1008 and 0x100A are only present in online dictionary, not in the offline one (ESI file)
-
CAP-716 Incorrect accesses and defaults of registers between products
-
CAP-686 Registers command source 1 and 2 must be RO
-
CAP-695 Registers store and restore all cannot be read
-
CAP-687 Analog gains and offsets have to be RW
-
CAP-241 Missing bootloader version register
-
CAP-621 Missing register restart all feedbacks
-
CAP-628 Reference angle offset register has to be RW
-
-
Communications:
-
Feedbacks
-
CAP-611 Drive gets stuck in fault state and is unable to reset it
-
CAP-528 Forced alignment might not work with analog command source selected
-
CAP-481 Minimum high side on time is necessary to generate output signal without distorsion at maximum duty
-
CAP-417 Correct value of register min low side time on
-
CAP-598 Incorrect implementation of derivative continuity feature
-
CAP-674 Following error bit is not updated correctly in statusword register
-
CAP-651 With ethernet, disturbance is sometimes not loading correctly
-
CAP-650 EtherCAT EEPROM product string name is wrong
-
CAP-635 CAP-CORE velocity filter should be 1 as default value
-
CAP-595 Derivative part of position PID is not working
-
CAP-567 PDO mapping and configuration are not stored into the NVM for CANopen version
-
CAP-542 Under temperature threshold has to be -20ºC
-
CAP-541 Communications watchdog error option code 2 and 3 are not working as expected
-
CAP-540 Interpolation time exponent not working properly and goes to 0
-
CAP-533 Brake frequency is not working
-
CAP-499 Ethernet link-activity LED signalling wrong behaviour
-
CAP-497 Port1 led should blink when having Ethernet application
-
CAP-413 Register Command source 1 cannot be stored in NVM
-
CAP-283 Correct EtherCAT CTT errors
-
CAP-694 Derivative filter of the control loop PID is wrong
-
CAP-443 Reset monitoring also reset disturbance
-
CAP-464 Motor temperature reading problems in several modes
Improvement
-
Monitoring and disturbance:
-
CAP-763 Remove monitoring buffer size limits
-
CAP-764 Protect monitoring read data form size 0
-
CAP-758 Add monitoring submodule version register
-
CAP-759 Add monitoring status additional bits
-
CAP-761 Create a monitoring status register
-
CAP-762 Add monitoring trigger status
-
CAP-768 Implement a mechanism to detect wrong update rate
-
-
CAP-521 Rename Force Boot register
-
CAP-438 CANopen bus off detection
-
CAP-333 Remove high side time on
-
CAP-311 Cable disconnection reaction is always fault and it should be configurable
-
CAP-643 Change default behavior of brake override
-
CAP-535 Missing COREs option code enums
-
CAP-506 Distinguish names on CANopen dictionary between manufacturer and CiA registers
-
CAP-723 Document error queue registers
-
CAP-699 Current quadrature/direct min/max output default values should be set to 48 V, not 24 V
-
CAP-524 EtherCAT and PWM PLL registers needs to be added
-
CAP-482 Create register to report maximum bus utilization
New Feature
-
CAP-641 Add if halt is active in the 15th bit of the status word
-
CAP-525 Fault reset input implementation
-
CAP-673 Add control loops error registers
-
CAP-523 Add Ethernet IP address configuration registers. IP address is now configurable
-
CAP-475 Implement link LED to CANopen FW (Ethernet)
-
CAP-708 Add functionality to enable or disable the +5V output of the drive
-
CAP-696 Add a protection in case packages are not received from an EtherCAT master
Known issues
|
ID |
Description |
Workaround |
|---|---|---|
|
CAP-738 |
Sometimes register Biss-C 2 frame size gives an error when writing it |
- |
|
CAP-734 |
Halt is not working properly in some modes (velocity, profile velocity and profile position) |
- |
|
CAP-730 |
Homing on current position with limits triggers positioning error |
Set the position inside the limits |
|
CAP-748 |
Motor temperature limits are not correct |
Configure a valid temperature sensor |
|
CAP-744 |
Kd filter should not take 0 value |
- |
|
CAP-741 |
Interpolation time exponent should not take negative values |
- |
|
CAP-752 |
Halt option code register (0x605D) can't be read and write |
Use manufacturer specific register 0x2620 |
|
CAP-605 |
EtherCAT register 0x6502 value is wrong |
- |
This version introduces new storable registers. It is necessary to follow a special update procedure:
-
Save the drive configuration to a file.
-
Restore the drive to defaults.
-
Update to the new firmware.
-
Load again the drive configuration from the previously saved file.
It may be necessary to redo the phasing.