Bug

  • CAP-1018 Wrong EtherCAT EMCY message when clearing a fault
  • CAP-1015 Voltage quadrature command stays around the initial value in CANopen
  • CAP-981 Index pulse of incremental encoder not working properly
  • CAP-840 Trapezoidal commutation is being inefficient

Improvement

  • CAP-975 Refactor of absolute feedback names
  • CAP-697 Object 0x1003 pre-defined error field wrong abort code when no error

New Feature

  • CAP-944 Add heartbeat consumer service in CANopen
  • CAP-943 Implement 0x603F error code register over CANopen
  • CAP-827 Implement 0x6062 position demand register
  • CAP-709 Read bootloader version from NVM

Known issues

IDDescriptionWorkaround
CAP-926Lower 3 bytes of the MAC address is not correct (CANopen)Do not create a LAN with more than one Capitan. If necessary, create a private LAN for each device.
Manufacturer specific Store/restore all return wrong error codes (CANopen)None
CAP-966

Default values read from the drive are not the same as those in the EDS file (CANopen)

None
CAP-967RPDO and TPODs registers have incorrect default values (CANopen)None
MOT3-2748Register 0x1003 subindex 1 returns an error code when connecting to the device using MotionLab 1.5.0 through CAN. It does not affect the drive functionality and will be fixed in future MotionLab release.None