Firmware 2.0.0

Bug

  • S-curve:

    • SUMMIT-2995 A positive velocity demand appears in a negative direction movement

    • SUMMIT-2806 At the end of a movement, the velocity demand is taking the velocity set-point value

    • SUMMIT-2801 High velocity command is sent when profile is latched

    • SUMMIT-2793 Acceleration discontinuity when latching new setpoints

    • SUMMIT-2792 Overshoot occurs when latching with non-zero initial velocities

    • SUMMIT-2303 When a profile position S-curve movement ends, velocity demand is set to profiler max. velocity instead of 0 rev/s

  • Object dictionary:

    • SUMMIT-2975 Some registers have incorrect names in extended versions

    • SUMMIT-2960 Bad access in some torque registers for extended versions

    • SUMMIT-2929 Reference angle offset register cannot be written

    • SUMMIT-2335 Motor temperature protection threshold has wrong data range

    • SUMMIT-2968 Remove deprecated current loop feedback bypass register

  • Feedbacks

    • SUMMIT-2858 Actual position is not computed correctly when absolute encoder position has 32 bits

    • SUMMIT-2840 Feedback runaway check is not working with absolute encoders

  • SUMMIT-2855 Following error bit is not updated correctly in statusword register

  • SUMMIT-3004 Reference angle offset has no limits

  • SUMMIT-2884 Derivative filter of the control loop PID is wrong

  • SUMMIT-2742 Incorrect implementation of derivative continuity feature

  • SUMMIT-2507 Halt functionality is not working

Improvement

  • SUMMIT-2838 Change default behavior of brake override

  • SUMMIT-2871 Applied new configuration to improve DC bus utilization and current sensing at high duties

  • SUMMIT-2872 Create register to report maximum bus utilization

  • SUMMIT-1886 Improve hardware configuration registers documentation

New Feature

  • SUMMIT-1670 Add control loops error registers

  • SUMMIT-2943 Add functionality to enable or disable the +5V output of the drive

  • SUMMIT-3046 Implement field weakening algorith

Known issues

ID

Description

Workaround

SUMMIT-3047

Halt is not working properly in some modes (velocity, profile velocity and profile position)

-

SUMMIT-3045

Motor temperature limits are not correct

Configure a valid temperature sensor

SUMMIT-3038

Kd filter should not take 0 value

-

SUMMIT-3059

Homing on current position with limits triggers positioning error

Set the position inside the limits

SUMMIT-3058

Interpolation time exponent should not take negative values

-

SUMMIT-3060

Missing public registers on extended products XDF files

-



This version introduces new storable registers. It is necessary to follow a special update procedure:

  • Save the drive configuration to a file.

  • Restore the drive to defaults.

  • Update to the new firmware.

  • Load again the drive configuration from the previously saved file.

It may be necessary to redo the phasing.