Bug
-
S-curve:
-
SUMMIT-2995 A positive velocity demand appears in a negative direction movement
-
SUMMIT-2806 At the end of a movement, the velocity demand is taking the velocity set-point value
-
SUMMIT-2801 High velocity command is sent when profile is latched
-
SUMMIT-2793 Acceleration discontinuity when latching new setpoints
-
SUMMIT-2792 Overshoot occurs when latching with non-zero initial velocities
-
SUMMIT-2303 When a profile position S-curve movement ends, velocity demand is set to profiler max. velocity instead of 0 rev/s
-
-
Object dictionary:
-
SUMMIT-2975 Some registers have incorrect names in extended versions
-
SUMMIT-2960 Bad access in some torque registers for extended versions
-
SUMMIT-2929 Reference angle offset register cannot be written
-
SUMMIT-2335 Motor temperature protection threshold has wrong data range
-
SUMMIT-2968 Remove deprecated current loop feedback bypass register
-
-
Feedbacks
-
SUMMIT-2858 Actual position is not computed correctly when absolute encoder position has 32 bits
-
SUMMIT-2840 Feedback runaway check is not working with absolute encoders
-
-
SUMMIT-2855 Following error bit is not updated correctly in statusword register
-
SUMMIT-3004 Reference angle offset has no limits
-
SUMMIT-2884 Derivative filter of the control loop PID is wrong
-
SUMMIT-2742 Incorrect implementation of derivative continuity feature
-
SUMMIT-2507 Halt functionality is not working
Improvement
-
SUMMIT-2838 Change default behavior of brake override
-
SUMMIT-2871 Applied new configuration to improve DC bus utilization and current sensing at high duties
-
SUMMIT-2872 Create register to report maximum bus utilization
-
SUMMIT-1886 Improve hardware configuration registers documentation
New Feature
-
SUMMIT-1670 Add control loops error registers
-
SUMMIT-2943 Add functionality to enable or disable the +5V output of the drive
-
SUMMIT-3046 Implement field weakening algorith
Known issues
|
ID |
Description |
Workaround |
|---|---|---|
|
SUMMIT-3047 |
Halt is not working properly in some modes (velocity, profile velocity and profile position) |
- |
|
SUMMIT-3045 |
Motor temperature limits are not correct |
Configure a valid temperature sensor |
|
SUMMIT-3038 |
Kd filter should not take 0 value |
- |
|
SUMMIT-3059 |
Homing on current position with limits triggers positioning error |
Set the position inside the limits |
|
SUMMIT-3058 |
Interpolation time exponent should not take negative values |
- |
|
SUMMIT-3060 |
Missing public registers on extended products XDF files |
- |
This version introduces new storable registers. It is necessary to follow a special update procedure:
-
Save the drive configuration to a file.
-
Restore the drive to defaults.
-
Update to the new firmware.
-
Load again the drive configuration from the previously saved file.
It may be necessary to redo the phasing.