Skip to main content
Skip table of contents

Firmware 2.0.0

Bug

  • S-curve:

    • SUMMIT-2995 A positive velocity demand appears in a negative direction movement

    • SUMMIT-2806 At the end of a movement, the velocity demand is taking the velocity set-point value
    • SUMMIT-2801 High velocity command is sent when profile is latched
    • SUMMIT-2793 Acceleration discontinuity when latching new setpoints

    • SUMMIT-2792 Overshoot occurs when latching with non-zero initial velocities

    • SUMMIT-2303 When a profile position S-curve movement ends, velocity demand is set to profiler max. velocity instead of 0 rev/s
  • Object dictionary:
    • SUMMIT-2975 Some registers have incorrect names in extended versions
    • SUMMIT-2960 Bad access in some torque registers for extended versions
    • SUMMIT-2929 Reference angle offset register cannot be written

    • SUMMIT-2335 Motor temperature protection threshold has wrong data range
    • SUMMIT-2968 Remove deprecated current loop feedback bypass register
  • Feedbacks
    • SUMMIT-2858 Actual position is not computed correctly when absolute encoder position has 32 bits
    • SUMMIT-2840 Feedback runaway check is not working with absolute encoders
  • SUMMIT-2855 Following error bit is not updated correctly in statusword register
  • SUMMIT-3004 Reference angle offset has no limits
  • SUMMIT-2884 Derivative filter of the control loop PID is wrong

  • SUMMIT-2742 Incorrect implementation of derivative continuity feature
  • SUMMIT-2507 Halt functionality is not working

Improvement

  • SUMMIT-2838 Change default behavior of brake override
  • SUMMIT-2871 Applied new configuration to improve DC bus utilization and current sensing at high duties
  • SUMMIT-2872 Create register to report maximum bus utilization

  • SUMMIT-1886 Improve hardware configuration registers documentation

New Feature

  • SUMMIT-1670 Add control loops error registers

  • SUMMIT-2943 Add functionality to enable or disable the +5V output of the drive

  • SUMMIT-3046 Implement field weakening algorith

Known issues

IDDescriptionWorkaround
SUMMIT-3047Halt is not working properly in some modes (velocity, profile velocity and profile position)-
SUMMIT-3045Motor temperature limits are not correctConfigure a valid temperature sensor
SUMMIT-3038Kd filter should not take 0 value-
SUMMIT-3059Homing on current position with limits triggers positioning errorSet the position inside the limits
SUMMIT-3058Interpolation time exponent should not take negative values-
SUMMIT-3060

Missing public registers on extended products XDF files

-


This version introduces new storable registers. It is necessary to follow a special update procedure:

  • Save the drive configuration to a file.
  • Restore the drive to defaults.
  • Update to the new firmware.
  • Load again the drive configuration from the previously saved file.

It may be necessary to redo the phasing.

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.