1.6.0
If your drive version is older than 1.5.0, use Motionlab 3 (1.3.0 version or higher) FTP bootloader tool to update it.
Using older Motionlab version will lock the drive permanently in bootloader state
Bug
- [SUMMIT-2039] - Homing and limit switch registers default value should be 0
 - [SUMMIT-2040] - STO config register has a value different from default
 - [SUMMIT-2041] - Store All and Restore All registers can't be read
 - [SUMMIT-2052] - Hall polarity not applied
 - [SUMMIT-2057] - Phase disconnection in BLDC should be shadowed
 - [SUMMIT-2097] - Reference phasing with dig. halls fails sometimes on boot-up
 - [SUMMIT-2105] - Profiler mode doesn't change correctly sometimes
 - [SUMMIT-2106] - Runaway happens when changing from velocity mode to position mode
 - [SUMMIT-2135] - Communication state control parameter cannot be modified by a NET/XCR user.
 - [SUMMIT-2136] - IP buffer is cleared using force clear but it cannot be filled until operation disable is requested
 - [SUMMIT-2143] - Storable communication watchdog register is not stored into NVM
 - [SUMMIT-2146] - Quick stop option code can have values out of scope
 - [SUMMIT-2147] - Some values of the Brake Activation/Holding Voltage Percentage registers are not well represented
 - [SUMMIT-2148] - Add BiSS-C gray BP3 frame type
 - [SUMMIT-2149] - The duty is generated with double of configured dead-time
 - [SUMMIT-2151] - Register 0x2618 cannot be written through EtherCAT SDO
 
New Feature
- [SUMMIT-2025] - Implement CANopen bootloader.
 - [SUMMIT-2088] - Add quick stop option as fault reaction code to keep the motor enabled at 0 rpm
 - [SUMMIT-2111] - Add latching bits for current loop errors and a bit for derating
 
Improvement
- [SUMMIT-1983] - Make PDO COBID storable and restore them if node id changes
 - [SUMMIT-2109] - Add warning information into the error list*
 - [SUMMIT-2141] - Add monitoring/disturbances info (Buffer size, frequency divider)
 - [SUMMIT-2150] - Increase feedback sampling determinism
 
SUMMIT-2109 *
Older motionlab version will show all warnings as an unknown error. Look for the error code on this page Error Management Everest
Known issues
ID  | Description  | Workaround  | 
|---|---|---|