Bug
-
SUMMIT-2611 Errors reported when accessing ETH params in EtherCAT
-
SUMMIT-2605 Serial number is not working properly
-
SUMMIT-2602 Position following error in EtherCAT and CAN 0x60F4 not corresponding with Motionlab values
-
SUMMIT-2601 Positioning option code 0x60F2 reads always 0 in EtherCAT and CAN
-
SUMMIT-2590 Correct MCBus vulnerability that makes that communications can be lost
-
SUMMIT-2557 0x6073 register does not work correctly
-
SUMMIT-2549 ESI file mismatches in FW versions >= 1.7.1. Add files for legacy products
-
SUMMIT-2543 CANopen lifeguard not working properly
-
SUMMIT-2516 Absolute encoder overflow does not work correctly when moving the motor
-
SUMMIT-2508 CANopen register 0x6077 (torque actual value) mapped in PDO crashes the drive
-
SUMMIT-2463 Power Stage actual maximum temperature takes value 0 when ambient temperature is negative
-
SUMMIT-2456 The actual position could be increased / decreased one undesired turn when absolute encoder polarity is inverted
-
SUMMIT-2438 Linear Motor Temperature sensor should not be affected by Pull-up value or pull-up voltage
-
SUMMIT-2416 Motor temperature sensor supplied at 3.3V are not correctly read
-
SUMMIT-2258 0x6078 register does not seem to work in EtherCAT firmware version
-
SUMMIT-2179 CANopen registers 0x6077 and 0x6078 can crash in PDO
-
SUMMIT-2033 Biss-C BP3 frame type is processing error bit as warning bit
New Feature
-
SUMMIT-2460 Add timeout in fault reaction state
-
SUMMIT-2600 Implement analog gain, offset and value
-
SUMMIT-2584 Adjust minimum temperatures
-
SUMMIT-2453 Add Fault reset functionality to general inputs
Improvement
-
SUMMIT-2483 Make velocity and position PID parameters PDO mappable
-
SUMMIT-2470 Create register to consult all the received BISS-C frame bits
-
SUMMIT-2380 Refactor all internal position variables to int32
-
SUMMIT-2360 Add the possibility to set a zero offset in absolute encoders
Known issues
|
ID |
Description |
Workaround |
|---|---|---|
|
SUMMIT-2407 |
Torque constant 0x5D00 is not stored from CAN/ECAT 0x1010 |
Use Motionlab store button for these parameters |
|
SUMMIT-2270 |
EMCY is not working and neither registers 0x1001 and 0x1003 |
Use manufacturer-specific registers for error management |
|
SUMMIT-2538 |
CANopen lifeguard ERR LED malfunctioning |
None. Is only visual, it does not affect correct functionality |
|
SUMMIT-2603 |
EtherCAT and CAN register 0x6502 value is wrong |
None |