2.5.0

Bug

MOCOAPP-68 Fix the Kd continuity

MOCOAPP-73 Profile acceleration/deceleration values are not properly calculated

MOCOAPP-5 Re-enable internal generator into auxiliary feedback list

MOCOAPP-62 Fault not detected while brake delay is active

COCOAPP-30 0xFF43 only appears on first PreOp to Op transition

As a result of this fix, register 0x5EC5 is no longer required

New Feature

MOCOAPP-65 Add a new register to limit max duty of phases

Improvement

MOCOAPP-80 Implemented new modulation for DC brushed motors

Known Issues

ID

Description

Workaraund

SUMMIT-3237

Wrong value conversion between homing speeds (CiA to manufacturer)

None

SUMMIT-3425

Feedback CLK not being reset after changing the refresh rate

None

EVR-995

Register 0x1001 does not properly reset when clearing a fault

None

EVR-964

Register 0x1029 Error behavior object not being stored

None

MOT3-2748

Register 0x1003 subindex 1 returns an error code when connecting to the device using MotionLab 1.5.0 through CAN. It does not affect the drive functionality and will be fixed in future MotionLab release.

None