Bug fixes

MOCOAPP-101 Make the STO reaction configurable via the STO Error Option Code register (0x263B).

MOCOAPP-103 Fix forced phasing after boot-up executed in the wrong operation mode.

EVR-1076 Remove error when wrong password is inserted in Store all (0x1010) and Restore (0x1011) all registers.

Improvement

MOCOAPP-102 Add a digital filter to STO inputs to avoid triggering false STO faults.

MOCOAPP-105 Charge bootstrap capacitors before PWM starts.

MOCOAPP-107 Remove electrical velocity limit of 600Hz.

Known issues

ID

Description

Workaround

SUMMIT-3237

Wrong value conversion between homing speeds (CiA to manufacturer).

None

SUMMIT-3425

Feedback CLK not being reset after changing the refresh rate.

None

EVS-193

Default MAC address is inverted.

None

MOT3-2748

Register 0x1003 subindex 1 returns an error code when connecting to the device using MotionLab 1.5.0 through CAN. It does not affect the drive functionality and will be fixed in future MotionLab release.

None