Skip to main content
Skip table of contents

Firmware 2.4.1

Bug

  • EVR-1024 'Brake holding voltage percentage' is mispelled

  • EVR-1025 'Brake Current Error Timeout' set to '0' does not disable following error protection

  • EVR-1028 Fix wrong behavior when both limit switches are active

  • EVR-1043 "Monitoring trigger type" options need to be updated

  • EVR-1046 Reading Store and Restore registers should return 1

  • EVEEXT-84 Fix Everest extended defaults and access

Improvement

  • EVR-1022 Add None option in brake control mode

  • EVR-1026 Rename the brake's duty control mode as voltage control mode

  • EVR-1039 Implement 'Brake Current Command' and 'Brake Current Actual Value' parameters

Known issues

ID

Description

Workaraund

SUMMIT-3237

Wrong value conversion between homing speeds (CiA to manufacturer)

None

SUMMIT-3372

Absolute encoder stops responding when reconnected

None

SUMMIT-3425

Feedback CLK not being reset after changing the refresh rate

None

EVR-954

Register 0x5EC5 does not keep modified values after store and power cycling in EtherCAT

None

EVR-995

Register 0x1001 does not properly reset when clearing a fault

None

EVR-964

Register 0x1029 Error behavior object not being stored

None

MOT3-2748

Register 0x1003 subindex 1 returns an error code when connecting to the device using MotionLab 1.5.0 through CAN. It does not affect the drive functionality and will be fixed in future MotionLab release.

None


JavaScript errors detected

Please note, these errors can depend on your browser setup.