2.4.0
New Feature
EVS-115 Implement 0x1029 Error behavior object
EVS-138 Detect a disconnected BiSS-C encoder
EVS-139 Add global system reset
EVS-142 Add support to configure STO error reaction
EVS-143 Add capability to detect a wrong ADC offset calibration
EVS-171 Add a new STO error to force stop the PWM if STO is activated in operation enable state
EVS-175 Add a new absolute encoder type based on SSI but with different scheme clocks
EVS-174 New error (0x0007385) triggered when the drive starts up in position mode outside of position limits
EVS-156 Implement brake current control
Bug
EVS-126 MAC address bytes are swapped
EVS-133 Lifeguard EMCY is not sent upon every lifeguard error
EVS-135 Warnings not being cleared from the system error queue
EVS-76 Communication cycle timeout register (0x5EC5) is not being stored in CANopen FW
EVS-131 EtherCAT link is lost after SW reset (from boot to application)
EVS-140 Review CiA variables mapping
EVS-160 Enable RPDO length error EMCY
EVS-177 Position mask is not being applied to absolute encoder frames
EVS-179 Everest return an incorrect configuration error when modifying some registers while motor is enabled
EVS-180 Bad EMCY message after CAN bus off
EVS-181 When forcing a CAN bus off state, the ERR LED is not steady on
EVS-188 Fix default values
EVS-191 CiA Positioning Following Error (0x60F4) is always reporting 0
EVS-128 Low layer CAN error has EMCY send disabled.
EVS-164 Incremental encoder 2 is disabled in NET builds
Improvement
EVS-136 Replace absolute encoder "wait cycles" by a "maximum refresh rate"
EVS-141 Allow transition from fault to switch on disabled if current scaling is changed
EVS-172 Control loops feedback options register should be RW
Known issues
ID | Description | Workaround |
---|---|---|
Wrong value conversion between homing speeds (CiA to manufacturer) | None | |
Absolute encoder stops responding when reconnected | None | |
Feedback CLK not being reset after changing the refresh rate | None | |
Sometimes the firmware version gets corrupted after restore | None | |
Default MAC address is inverted | None | |
Register 0x1003 subindex 1 returns an error code when connecting to the device using MotionLab 1.5.0 through CAN. It does not affect the drive functionality and will be fixed in future MotionLab release. | None |