2.4.1
Bug
EVS-192 Sometimes the firmware version number gets corrupted
EVS-209 'Brake holding voltage percentage' is misspelled
EVS-210 'Brake Current Error Timeout' set to '0' does not disable following error protection
EVS-212 Fix wrong behavior when both limit switches are active
Improvement
EVS-208 Add None option in brake control mode
EVS-211 Rename the brake's duty control mode as voltage control mode
EVS-216 Implement 'Brake Current Command' and 'Brake Current Actual Value' parameters
Known issues
ID | Description | Workaround |
---|---|---|
Wrong value conversion between homing speeds (CiA to manufacturer) | None | |
Absolute encoder stops responding when reconnected | None | |
Feedback CLK not being reset after changing the refresh rate | None | |
Default MAC address is inverted | None | |
Register 0x1003 subindex 1 returns an error code when connecting to the device using MotionLab 1.5.0 through CAN. It does not affect the drive functionality and will be fixed in future MotionLab release. | None |