0x217C - Set feedback power supply status



Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x217C

0x00

Set feedback power supply status

UINT16

RW

No

No

Data type

1

-

This register allows to enable or disable the power of the feedbacks and I/O.

Some drivers include a controllable 5 V / 3.3 V output thought to supply feedbacks and I/O. This is detailed in Product Manual.

Disable the power of the feedbacks could be used to reduce the power consumption when the drive is in stand-by mode.

The allowed values for this parameter are:

Value

Meaning

0

Disable the power of the feedbacks and I/O

1

Enable the power of the feedbacks and I/O


Warning

This parameter cannot be changed while the power stage is enabled.


If this parameters remains disable it is not possible to read any feedback as they will not be powered.