0x21E0 - Max. current

Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x21E0

0x00

Max. current

FLOAT

RW

Yes

Yes

Data type

24.0

A

This register sets the maximum allowed instant current.

By default, this register limits current set-points injected to the current control loops above the max current level. However if the current loop is not enabled it works as a fault: if the measured current is higher than this value the drive shut down the power stage.

This protection is active if at least the current loop is enabled. Therefore it works for all current, velocity and position modes, but it is inactive in voltage mode.


Max current limit is applied to the total motor current →