Skip to main content
Skip table of contents

0x260B - Quick stop option code

Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x260B

0x00

Quick stop option code

INT16

RW

No

Yes

Data type

5

-

This parameter indicates the reaction of the quick stop when it is called.

Value

Action

0

Disable power stage

1

Slow down ramp and disable

2

Quick stop ramp and disable

5

Slow down ramp

6

Quick stop ramp

Note

Slow down ramp uses deceleration defined in the profiler configuration, while Quick stop ramp uses the Quick stop deceleration.

When using slow down ramp or quick stop ramp option codes, it is important to have the velocity loop operative and properly configured. In the option codes that also disable the power stage after detecting that the motor has stopped, velocity threshold and velocity threshold time have to be also configured.