0x620 - Halt option code



Address

Name

Data Type

Access

Cyclic access

NVM

Value range

Default value

Units

0x620

Halt option code

INT16

RW

No

Yes

0 - 2

0

-

This parameter indicates the reaction of the halt when it is triggered.


Value

Action

0

None

1

Slow down ramp

2

Quick stop ramp


Note

Slow down ramp uses deceleration defined in the profiler configuration, while Quick stop ramp uses the Quick stop deceleration.


Warning

This parameter cannot be changed while the power stage is enabled


When using slow down ramp or quick stop ramp option codes, it is important to have the velocity loop operative and properly configured. In the option codes that also disable the power stage after detecting that the motor has stopped, velocity threshold and velocity threshold time have to be also configured.