Skip to main content
Skip table of contents

XCR - Installation

Unboxing

When unboxing the drive please ensure the following:

  • Remove it from the bag carefully.
  • Check that there is no visible physical damage. If any, report it immediately to the carrier.
  • Check the part number of the drive on the side label. 

Installation Safety Requirements

The drive has live circuits that can be touched and entail a risk of electric shock (Protective Class 0), as well as a risk of thermal injury. It must be mounted on a closed electrical operating area to which access is restricted to skilled or instructed personnel. This enclosure, cabinet, protection, or case should have a minimum Index of Protection of IP3X. To ensure electrical safety it is also important that the environment is clean from conductive pollution or condensation when the drive is powered (Pollution degree 2). 



WARNING HOT SURFACES!

The drive and motor can become hot and cause severe burns. 

If any of the user-accessible surfaces exceeds 70ºC, a hot-surface signal must be added. This is the responsibility of the installer. 

ATTENTION, le moteur peut être chaud.

Le moteur peut devenir très chaud > 70ºC pendant le fonctionnement. Ne le touchez pas directement pour éviter les brûlures ! L'utilisation de la sonde de température est fortement recommandée.


DANGER, ELECTRIC SHOCK!

Power and motor pins have live voltages which can exceed 50 V which can cause electric shock!

Perform installation procedures without voltage. Ensure the drive is mounted on a closed electrical operating area which protects against direct contact. 

ATTENTION, surcharge du moteur.

L'Everest XCR peut laisser passer des courants qui peuvent endommager ou provoquer un incendie du moteur. Veillez toujours à ce que les courants nominaux continus et de pointe du moteur soient respectés en effectuant des réglages lors de la configuration du variateur.

The drive may be operated without enclosure and protection against electric shock when it is supplied at Extra Low Voltage (ELV), ≤ 50 V.