0x2436 - Internal generator cmd source

Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x2436

0x01

Function type

UINT8

RW

No

No

UINT8

0

-

0x2436

0x02

Amplitude

UINT32 (from release 2.3.4, otherwise UINT16)

RW

No

Yes

UINT32

1000

Motion units

0x2436

0x03

Frequency (10 mHz)

UINT16 (from release 2.3.4, otherwise UINT8)

RW

No

Yes

UINT16

10

10 mHz

0x2436

0x04

Digital output signaling

(Deprecated from version 1.3.0)

UINT8

RW

No

Yes

UINT8

0

-

EMCL includes an internal signal generator to allow performing repetitive movements without the need of an external master.

It can be used only in Cyclic synchronous modes.

SubIndex description:

  • 0x01 (Function type): The register value has the following meaning:

    Value

    Definition

    0

    Sinusoidal signal

    1

    Reserved

    2

    Square signal

    3…255

    Reserved

    Sinusoidal signal is only available for Cyclic synchronous position mode.

  • 0x02 (Amplitude): Select the peak amplitude, expressed in motion units (‰ of rated torque, position counts or velocity counts/s), of the generated signal.

  • 0x03 (Frequency): Select the frequency, expressed in 10 mHz, of the generated signal. (i.e. default value '10' on this register, means a frequency of 100 mHz)