0x2436 - Internal generator cmd source

Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x2436

0x01

Function type

UINT8

RW

No

No

UINT8

0

-

0x24360x02AmplitudeUINT32 (from release 2.3.4, otherwise UINT16)RWNoYesUINT321000Motion units
0x24360x03Frequency (10 mHz)UINT16 (from release 2.3.4, otherwise UINT8)RWNoYesUINT161010 mHz
0x24360x04

Digital output signaling

(Deprecated from version 1.3.0)

UINT8RWNoYesUINT80-

EMCL includes an internal signal generator to allow performing repetitive movements without the need of an external master.

It can be used only in Cyclic synchronous modes.

SubIndex description:

  • 0x01 (Function type): The register value has the following meaning:

    Value

    Definition

    0

    Sinusoidal signal

    1

    Reserved

    2Square signal
    3…255Reserved

    Sinusoidal signal is only available for Cyclic synchronous position mode.

  • 0x02 (Amplitude): Select the peak amplitude, expressed in motion units (‰ of rated torque, position counts or velocity counts/s), of the generated signal.
  • 0x03 (Frequency): Select the frequency, expressed in 10 mHz, of the generated signal. (i.e. default value '10' on this register, means a frequency of 100 mHz)
  • 0x04 (Digital output signaling): Allows to generate a signaling using general purpose digital outputs according to generated signal. Writing a 1 will select Digital output 1, etc. Digital output will be active half of the period. Writing a zero will disable the signaling.