Skip to main content
Skip table of contents

0x2A03 - Analog inputs

Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x2A03

0x01

Analog input 1 value

UINT32

RO

Yes

No

UINT32

-

ADC counts

0x2A03

0x02

Analog input 2 value

UINT32

RO

Yes

No

UINT32

-

ADC counts

0x2A03

0x03

Analog input 3 value

UINT32

RO

Yes

No

UINT32

-

ADC counts

0x2A03

0x04

Analog input 4 value

UINT32

RO

Yes

No

UINT32

-

ADC counts

This object indicates the result of the analog to digital conversion.

The value is represented in counts of the ADC (the resolution of the ADC is 12 bits, and the voltage range will depend on the hardware).

Not all ingenia controllers include four Analog inputs. Please refer to Installation manual for further information.