0x2A03 - Analog inputs
Index | Sub Index | Name | Data Type | Acc. | Pdo Map. | NVM | Value range | Default value | Units |
---|---|---|---|---|---|---|---|---|---|
0x2A03 | 0x01 | Analog input 1 value | UINT32 | RO | Yes | No | UINT32 | - | ADC counts |
0x2A03 | 0x02 | Analog input 2 value | UINT32 | RO | Yes | No | UINT32 | - | ADC counts |
0x2A03 | 0x03 | Analog input 3 value | UINT32 | RO | Yes | No | UINT32 | - | ADC counts |
0x2A03 | 0x04 | Analog input 4 value | UINT32 | RO | Yes | No | UINT32 | - | ADC counts |
This object indicates the result of the analog to digital conversion.
The value is represented in counts of the ADC (the resolution of the ADC is 12 bits, and the voltage range will depend on the hardware).
Not all ingenia controllers include four Analog inputs. Please refer to Installation manual for further information.