Skip to main content
Skip table of contents

0x2504 - Torque demand low pass filter

Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x2504

0x01

Filter enabled

UINT8

RW

No

Yes

0 or 1

0

-

0x2504

0x02

Cutoff frequency

UINT16

RW

No

Yes

0 to 1500

100

Hz

This object configures all parameters related to the torque demand filter. 

 

The filter is a first order low pass filter in which the cutoff frequency (the frequency where the output is attenuated 3 dB) is configurable. It is situated before the torque loop, see Torque for further information. 

 

SubIndex description:

  • 0x01 (Filter enabled): It indicates if the filter is enabled or disabled. Writing a one will enable the torque demand filter.
  • 0x02 (Cutoff frequency): It indicates the desired cutoff frequency for the low pass filter.