0x2A11 - GPO mapping parameter

Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x2A11

0x01

GPO 1 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x02

GPO 2 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x03

GPO 3 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x04

GPO 4 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x05

GPO 5 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x06

GPO 6 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x07

GPO 7 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x08

GPO 8 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x09

GPO 9 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x0A

GPO 10 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

The value of this register will indicate the which function is attached to the related GPO.

The functions available are:

Function

Value

GPO

0

Brake

1

Health

2

Internal limit

3

Target reached

4

Internal generator

5

PWM output 1

6

PWM output 2

7

Digital to Analog converter

8

External shunt braking resistor

9

Some Ingenia drives has a dedicated output for shunt braking resistor management. The functionality of this output cannot be changed. Please refer to the product manual of the drive.

If an output has a PWM output function attached, use the register 0x2A0B - PWM outputs to set the period and duty.

The same function can be mapped to different GPO.