0x2A11 - GPO mapping parameter

Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x2A11

0x01

GPO 1 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x02

GPO 2 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x03

GPO 3 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x04

GPO 4 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x05

GPO 5 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x06

GPO 6 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x07

GPO 7 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x08

GPO 8 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x09

GPO 9 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

0x2A11

0x0A

GPO 10 mapping parameter

 UINT16

RW

No

Yes

0 to 9

0

-

The value of this register will indicate the which function is attached to the related GPO.

The functions available are:

FunctionValue
GPO0
Brake1
Health2
Internal limit

3

Target reached4
Internal generator5
PWM output 16
PWM output 27
Digital to Analog converter8
External shunt braking resistor9

Some Ingenia drives has a dedicated output for shunt braking resistor management. The functionality of this output cannot be changed. Please refer to the product manual of the drive.

If an output has a PWM output function attached, use the register 0x2A0B - PWM outputs to set the period and duty.

The same function can be mapped to different GPO.