Skip to main content
Skip table of contents

0x2D00 - Open loop parameters

Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x2D00

0x01

Target voltage

INT16

RW

Yes

No

INT16

0x0000

Dc bus / 32767

0x2D00

0x02

Target frequency

UINT16

RW

Yes

No

UINT16

0x0000

mHz

This object contains all necessary parameters to work with both Open loop vector and Open loop scalar modes. 

 

The target voltage allows assigning the voltage used in open loop vector/scalar mode. Target voltage equal to zero will not apply any voltage to the motor. In the same way a target voltage equal to 32767 will inject the maximum voltage in a sense and -32767 will apply the maximum voltage in opposite sense.

The target frequency is only used in open loop scalar mode to assign the commutation frequency (for BLDC, BLAC and AC Induction motors).