EMC Compliance
|
IEC 61800-3:2017: Adjustable speed electrical power drive systems. Part 3: EMC requirements and specific test methods
-
CISPR 16-1-2:2014 + CISPR 11:2015 + A1:2016: Conducted emissions: EN 61800-3 Category C2
-
CISPR 22:2015: Conducted emissions for Ethernet fieldbus standard: EN 55022 Class B
-
CISPR 16-1-4:2010 + CISPR 11:2015 + A1:2016: Electromagnetic radiation emissions: EN 55032 Class B, EN 61800-3 Category C3
IEC 61000-6-2:2016: Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
-
IEC 61000-4-2:2008: ESD (electrostatic discharge) disturbances: Performance criterion B.
-
IEC 61000-4-3:2006: Radio-frequency electromagnetic field disturbances, amplitude modulated 80 MHz to 2,7 GHz: Performance criterion A.
-
IEC 61000-4-4:2012: Fast transients disturbances: Performance criterion B.
-
IEC 61000-4-6:2013: Conducted radio frequency disturbances common mode 150 kHz to 80 MHz: Performance criterion A.
IEC 61800-5-2:2016: Adjustable speed electrical power drive systems. Part 5-2: Safety requirements – Functional, Clause 9.3 (Immunity Testing)
-
IEC 61000-4-2:2008: ESD (electrostatic discharge) disturbances: Performance criterion Functional Safe.
-
IEC 61000-4-3:2006 + AMD1:2007 + AMD2:2010: Radio-frequency electromagnetic field disturbances, amplitude modulated 80 MHz to 2,7 GHz: Performance criterion Functional Safe.
-
IEC 61000-4-4:2012: Fast transients disturbances: Performance criterion Functional Safe.
-
IEC 61000-4-6:2013: Conducted radio frequency disturbances common mode 150 kHz to 80 MHz: Performance criterion Functional Safe.
|
|
Environmental Testing Compliance
|
IEC 60068-2-1:2007: Test Ad, Cold
IEC 60068-2-2:2007: Test Be, Dry Heat
IEC 60068-2-38:2009: Test Z/AD, Composite temperature / humidity cyclic
IEC 60068-2-78:2012: Test Cab, Damp heat, steady state
IEC 60068-2-6:2007: Test Fc: Vibration (sinusoidal)
IEC 60068-2-27:2008: Test Ea: Shock
|