0.5.0

Bug

  • CAP-297 Some registers are not being stored

  • CAP-296 Registers 0x709 and 0x70A are not loading its default value

  • CAP-293 Reference angle offset cannot be written and its value is not well computed when doing phasing

  • CAP-287 Cannot read FW version in Motionlab (EoE)

  • CAP-286 Power stage temp 3 reads 0 when mapped to a PDO

  • CAP-245 ECAT store is not storing rated current

  • CAP-233 Quick stop option code is not working

  • CAP-212 EtherCAT cable disconnection safety reaction not working

  • CAP-206 PDO mappings and PDO assigns have no default value

Improvement

  • CAP-248 Monitoring byte access instead of block

  • CAP-231 Refactor all internal position variables to int32

New Feature

  • CAP-237 Positioning option code is not implemented

  • CAP-236 Halt option code is not implemented

Known issues

ID

Description

workaround

CAP-211

EMCY is not working and neither registers 0x1001 and 0x1003

Use manufacturer-specific registers for error management.

  • Last Error

  • Error total number

  • Error list index request

  • Error list requested code

CAP-215

Max and min position limits not working

None.

CAP-311

Cable disconnection reaction is always fault

None.

CAP-313

Register BiSS2 frame size is not being stored

If using BiSS-C 2, re-configure BiSS-C 2 frame after power up before operation.