2.2.1

Bug

  • EVR-901 Derivative part of the PIDs can add undesired dynamics when it is supposed to be deactivated

  • EVR-896 CTT error resulted from test from eve-xcr-c running 2.2.1.34

  • EVR-888 Wrong absolute encoder registers ranges

  • EVR-868 0x607B and 0x607D registers are not being updated in CDM when modified from ML3

  • EVR-863 Activating a default PDO makes lost communication with drive

  • EVR-856 Missing enum for register set feedback power supply status

  • EVR-804 Drive can't buffer more than one EMCY message

  • EVR-803 Ping is not working with EoE configured

  • EVR-797 CiA402 conversions are not correctly initialized at startup, it is needed to read certain registers to prevent this

  • EVR-796 ECAT maximum size mapping wrong behavior

  • EVR-794 Max current CiA register has wrong units, A instead of ‰ rated current

  • EVR-774 The MAC address (coming from the ECAT master) is not taken by the drive

  • EVR-771 Added external error enum into XDF

  • EVR-760 Halt is not working properly in some modes

New Feature

  • EVR-836 Add global system reset for NET and XCR variants


Known issues

ID

Description

Workaraund

EVR-898

Manufacturer specific Store/restore all return wrong error codes (CANopen)

None

EVR-898

Default values read from the drive are not the same as those in the EDS file (CANopen)

None

EVR-875

Register comms cycle timeout 0x5EC5 is not being stored in CAN FW

None

EVR-855

Registers monitoring-disturbance channel map cannot be written

None