0x605A - Quick stop option code
This object indicates what action is performed when the quick stop function is executed.
Index | Sub Index | Name | Data Type | Acc. | Pdo Map. | NVM | Value range | Default value | Units |
---|---|---|---|---|---|---|---|---|---|
0x605A | 0x00 | Quick stop option code | INT16 | RW | No | Yes | INT16 | 6 | - |
Data description:
The register value has the following meaning:
Value | Quick stop option |
---|---|
-1 | Slow down on motor phases short-circuit and stay in quick stop active |
6 | Slow down on quick stop ramp and stay in quick stop active |
Different values than the specified are reserved and should not be used.