0x605A - Quick stop option code

This object indicates what action is performed when the quick stop function is executed.


Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x605A

0x00

Quick stop option code

INT16

RW

No

Yes

INT16

6

-

 



Data description:
The register value has the following meaning:

Value

Quick stop option

-1

Slow down on motor phases short-circuit and stay in quick stop active

6

Slow down on quick stop ramp and stay in quick stop active

Different values than the specified are reserved and should not be used.