This object indicates what action is performed when the quick stop function is executed.
|
Index |
Sub Index |
Name |
Data Type |
Acc. |
Pdo Map. |
NVM |
Value range |
Default value |
Units |
|---|---|---|---|---|---|---|---|---|---|
|
0x605A |
0x00 |
Quick stop option code |
INT16 |
RW |
No |
Yes |
INT16 |
6 |
- |
Data description:
The register value has the following meaning:
|
Value |
Quick stop option |
|---|---|
|
-1 |
Slow down on motor phases short-circuit and stay in quick stop active |
|
6 |
Slow down on quick stop ramp and stay in quick stop active
|
Different values than the specified are reserved and should not be used.