Skip to main content
Skip table of contents

0x60E0 - Positive torque limit value

Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x60E0

0x00

Positive torque limit value

INT16

RW

Yes

Yes

INT16

1000

‰ rated torque 

This object indicates the configured maximum positive torque in the motor.

 

This register together with negative torque limit allows configuring the system with an asymmetrical torque limit window.