Address |
Name |
Data Type |
Access |
Cyclic access |
NVM |
Value range |
Default value |
Units |
|---|---|---|---|---|---|---|---|---|
|
0x17C |
Set feedback power supply status |
UINT16 |
RW |
No |
No |
Data type |
1 |
- |
This register allows to enable or disable the power of the feedbacks and I/O.
Some drivers include a controllable 5 V / 3.3 V output thought to supply feedbacks and I/O. This is detailed in Product Manual.
Disable the power of the feedbacks could be used to reduce the power consumption when the drive is in stand-by mode.
The allowed values for this parameter are:
|
Value |
Meaning |
|---|---|
|
0 |
Disable the power of the feedbacks and I/O |
|
1 |
Enable the power of the feedbacks and I/O |
This parameter cannot be changed while the power stage is enabled.
If this parameters remains disable it is not possible to read any feedback as they will not be powered.