Address

Name

Data Type

Access

Cyclic access

NVM

Value range

Default value

Units

0x401

Primary Absolute Slave 2 (daisy chain) - Error tolerance

UINT16

RW

No

Yes

Data type

5

cycles

This register indicates the total number of wrong frame readings tolerated by the drive before generating a fault.


Setting a 0 value will ignore any error from the encoder.