0x026 - Profiler max. acceleration



Address

Name

Data Type

Access

Cyclic access

NVM

Value range

Default value

Units

0x026

Profiler max. acceleration

FLOAT

RW

Yes

Yes

> 0.0

20.0

rev / s2

This register configures the profiler maximum acceleration.


Warning

Profiler max. acceleration must have positive values, otherwise behavior will be unpredictable.