Address

Name

Data Type

Access

Cyclic access

NVM

Value range

Default value

Units

0x07F

Current loop feedback bypass

UINT16

RW

No

No

0 to 1

0

-

This register allows bypassing the current feedback in the current loops, and setting the current readings to 0. This allows using the current loops in open loop.

MeaningValue
Current feedback connected0
Current feedback bypassed1