Skip to main content
Skip table of contents

0x1DE - Min position range limit

Address

Name

Data Type

Access

Cyclic access

NVM

Value range

Default value

Units

0x1DE

Min position range limit

INT32

RW

Yes

Yes

Data type

-

encoder counts

This register sets the minimum position range limit. On reaching or exceeding these range limits, the position set-point and position actual wrap automatically to the other end of the range.

This limits are disabled if both registers Min position range limit and Max position range limit are set to 0.

If software position limits and position range limits are enabled, the more restricted is applied. Software position limits are chosen in case of conflict: