0x613 - Power stage user over-temperature error option code



Address

Name

Data Type

Access

Cyclic access

NVM

Value range

Default value

Units

0x613

Power stage user over-temperature error option code

UINT16

RW

No

Yes

0 - 3

0

-

This register set the drive fault reaction for an user over-temperature detection.

The value of this register determines the reaction of the drive when a fault is triggered:

Option Code

Severity

Reaction

0

Fault

Disable power stage

1

Warning

Do nothing

2

Fault

Slow down ramp

3

Fault

Quick stop ramp


Further information in Error management.


When using slow down ramp or quick stop ramp option codes, it is important to have the velocity loop operative and properly configured. In the option codes that also disable the power stage after detecting that the motor has stopped, velocity threshold and velocity threshold time have to be also configured.