Skip to main content
Skip table of contents

0x07D - Current direct loop input offset

Address

Name

Data Type

Access

Cyclic access

NVM

Value range

Default value

Units

0x07D

Current direct loop input offset

FLOAT

RW

Yes

Yes

Data type

0.0

A

This register adds an offset to the filtered reference of the current direct loop controller.

Warning

When the commutation modulation type parameter is set to Brushless DC or Brushed DC, only the current quadrature control is used. However, both of the current inputs (direct and quadrature) are still used for processing some protections (I2T, derating). In this case, make sure the current direct set-point and current direct loop input offset are set to 0