Skip to main content
Skip table of contents

0x605A - Quick stop option code


Index

Sub Index

Name

Data Type

Acc.

Pdo Map.

NVM

Value range

Default value

Units

0x605A

0x00

Quick stop option code

INT16

RW

No

Yes

INT16

5

-

This object indicates what action is performed when the quick stop function is executed.

Data description:
The register value has the following meaning:

Value

Quick stop option

0

Disable power stage

1

Slow down ramp and disable

2

Quick stop ramp and disable

5

Slow down ramp

6

Quick stop ramp

Different values than the specified are reserved and should not be used.

Note

Slow down ramp uses deceleration defined in the profiler configuration, while Quick stop ramp uses the Quick stop deceleration.

When using slow down ramp or quick stop ramp option codes, it is important to have the velocity loop operative and properly configured. In the option codes that also disable the power stage after detecting that the motor has stopped, velocity threshold and velocity threshold time have to be also configured.

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.